Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Discrete depth profiles of water temperature, dissolved oxygen, oxidation-reduction potential, conductivity, specific conductance, and pH were collected with multiple handheld water quality probes and discrete depth profiles of photosynthetically active radiation (PAR) were collected with a LI-COR underwater light meter from 2013 to 2024 in five drinking water reservoirs in southwestern Virginia, USA. These reservoirs are: Beaverdam Reservoir (Vinton, Virginia), Carvins Cove Reservoir (Roanoke, Virginia), Falling Creek Reservoir (Vinton, Virginia), Gatewood Reservoir (Pulaski, Virginia), and Spring Hollow Reservoir (Salem, Virginia). Beaverdam, Carvins Cove, Falling Creek, and Spring Hollow Reservoirs are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia, and Gatewood Reservoir is a drinking water source for the Town of Pulaski, Virginia. All discrete depth profiles were collected on approximately 1-meter intervals. The data package consists of two datasets: 1) Secchi depth data; and 2) discrete depth profiles of multiple water quality variables measured by handheld sensors. The Secchi data and discrete depth profiles were measured at the deepest site of each reservoir adjacent to the dam, as well as other in-reservoir sites. Handheld sensor measurements were also collected at a gauged weir on the primary inflow tributary, other inflows, and outflows at Falling Creek Reservoir; inflows and outflows at Beaverdam Reservoir; and inflows at Carvins Cove Reservoir. In 2021, YSI handheld data were also collected from a littoral site in Beaverdam Reservoir. Data were collected approximately fortnightly in the spring months (March - May), weekly in the summer and early autumn (June - September), and monthly in the late autumn and winter (October - February) in Falling Creek and Beaverdam Reservoirs; data coverage in the other three reservoirs varies among years. Note there are some YSI depth profiles and Secchi observations that were measured at night during overnight sampling. All of these observations have the correct time associated with them. There was a major revision of this dataset from its previous version, which included correcting times of observations, including values of negative ORP, and adding observations from an outflow at Falling Creek Reservoir.more » « less
-
Sediment traps were deployed to assess the mass and composition (lithium, sodium, magnesium, aluminum, potassium, calcium, iron, manganese, copper, strontium, barium, total organic carbon, and total nitrogen) of settling particulates in the water column of two drinking water reservoirs—Beaverdam Reservoir and Falling Creek Reservoir, both located in Vinton, Virginia, USA. Sediment traps were deployed at two depths in each reservoir to capture both epilimnetic and hypolimnetic (total) sediment flux. The particulates were collected from the traps approximately fortnightly from April to December from 2018 to 2023, then filtered, dried, and analyzed for lithium, sodium, magnesium, aluminum, potassium, calcium, iron, manganese, copper, strontium, and barium (2018 to 2023) and total organic carbon and total nitrogen (2018 to 2022, due to instrument repairs). Beaverdam and Falling Creek are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia. The sediment trap dataset consists of logs detailing the sample filtering process, the mass of dried particulates from each filter, and the raw concentration data for lithium (Li), sodium (Na), magnesium (Mg), aluminum (Al), potassium (K), calcium (Ca), iron (Fe), manganese (Mn), copper (Cu), strontium (Sr), barium (Ba), total organic carbon (TOC) and total nitrogen (TN). The final products are the calculated downward fluxes of solid Li, Na, Mg, Al, K, Ca, Fe, Mn, Cu, Sr, Ba, TOC, and TN during the aforementioned deployment periods.more » « less
-
Discrete depth profiles of water temperature, dissolved oxygen, oxidation-reduction potential, conductivity, specific conductance, and pH were collected with various handheld YSI water quality probes and discrete depth profiles of photosynthetically active radiation (PAR) were collected with a LI-COR underwater light meter from 2013 to 2023 in five drinking water reservoirs in southwestern Virginia, USA. These reservoirs are: Beaverdam Reservoir (Vinton, Virginia), Carvins Cove Reservoir (Roanoke, Virginia), Falling Creek Reservoir (Vinton, Virginia), Gatewood Reservoir (Pulaski, Virginia), and Spring Hollow Reservoir (Salem, Virginia). Beaverdam, Carvins Cove, Falling Creek, and Spring Hollow Reservoirs are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia, and Gatewood Reservoir is a drinking water source for the Town of Pulaski, Virginia. All YSI and PAR depth profiles were collected on approximately 1-meter intervals. The data package consists of two datasets: 1) Secchi depth data; and 2) YSI and PAR profiles. The Secchi depths and YSI and PAR depth profiles were measured at the deepest site of each reservoir adjacent to the dam and other in-reservoir transects. YSI measurements were also collected at a gauged weir on the primary inflow tributary, other inflows and outflows at Falling Creek, inflows and outflows at Beaverdam, and inflows at Carvins Cove. In 2021, YSI profiles were also collected from a littoral site in Beaverdam. Data were collected approximately fortnightly in the spring months (March - May), weekly in the summer and early autumn (June - September), and monthly in the late autumn and winter (October - February) in Falling Creek and Beaverdam Reservoirs; data coverage in the other three reservoirs varies among years. Note there are some YSI profiles and Secchi observations that were measured at night during overnight sampling. All of these observations have the correct time associated with them. There was a major revision of this dataset from version 11, which includes correcting times of observations, including negative ORP values, and adding observations from an outflow at Falling Creek Reservoir.more » « less
An official website of the United States government
